ᱵᱩᱭ-ᱞᱮᱠᱟᱱ ᱫᱟᱜ ᱜᱩᱱ ᱧᱮᱞ ᱛᱚᱞᱟᱥ ᱥᱴᱮᱥᱚᱱ

May 06, 2026

ᱢᱤᱫ ᱱᱟᱶᱟ ᱚᱱᱚᱞ

ᱥᱚᱞᱟᱨ ᱯᱟᱣᱟᱨ ᱥᱟᱯᱞᱟᱭ ᱥᱤᱥᱴᱚᱢ ᱟᱨ ᱢᱟᱞᱴᱤ-ᱯᱮᱨᱟᱢᱤᱴᱟᱨ ᱢᱚᱱᱤᱴᱚᱨᱤᱝ ᱴᱮᱠᱱᱚᱞᱚᱡᱤ ᱮᱯᱞᱤᱠᱮᱥᱚᱱ

 

ᱵᱚᱭ-ᱞᱮᱠᱟᱱ ᱫᱟᱜ ᱜᱩᱱ ᱧᱮᱞ ᱥᱴᱮᱥᱚᱱ ᱫᱚ ᱥᱟᱹᱨᱤ-ᱚᱠᱛᱚ ᱫᱟᱜ ᱯᱟᱨᱤᱵᱮᱥ ᱧᱮᱞ ᱞᱟᱹᱜᱤᱫ ᱢᱤᱫ ᱢᱩᱲᱩᱫ ᱥᱟᱫᱷᱚᱱ ᱠᱟᱱᱟ᱾ ᱥᱚᱞᱟᱨ ᱫᱟᱲᱮ ᱥᱟᱨᱵᱦᱟᱨ ᱟᱨ ᱢᱟᱞᱴᱤ-ᱯᱮᱨᱟᱢᱤᱴᱟᱨ ᱥᱮᱱᱥᱟᱨ ᱠᱚ ᱢᱤᱫᱴᱟᱝ ᱛᱮ, ᱱᱚᱣᱟ ᱫᱚ ᱫᱟᱜ ᱯᱟᱨᱤᱵᱮᱥᱛᱟ ᱨᱮᱭᱟᱜ ᱡᱷᱟᱹᱞ -ᱵᱤᱱ ᱧᱮᱞ ᱧᱮᱧᱮᱞ ᱞᱟᱹᱜᱤᱫ ᱮ ᱜᱚᱲᱚᱣᱟᱜᱼᱟ᱾ ᱱᱚᱶᱟ ᱦᱚᱨᱟ ᱫᱚ ᱢᱤᱫ ᱜᱩᱞᱟᱹᱭ ᱯᱷᱞᱚᱴ ᱵᱮᱵᱚᱦᱟᱨ ᱮᱫᱟ, ᱡᱟᱦᱟᱸ ᱨᱮ COD, ᱟᱢᱚᱱᱤᱭᱟ ᱱᱟᱭᱴᱨᱚᱡᱮᱱ, ᱞᱚᱞᱚ, pH, ᱜᱩᱲᱩᱵ ᱚᱠᱥᱤᱡᱮᱱ, ᱴᱟᱨᱵᱤᱰᱤᱴᱤ, ᱟᱨ ᱠᱚᱱᱰᱟᱠᱴᱤᱵᱷᱤᱴᱤ ᱠᱚ ᱢᱤᱫ ᱥᱟᱶᱛᱮ ᱢᱮᱱᱟᱜ-ᱟ᱾ ᱠᱚᱢ-ᱯᱟᱣᱟᱨ ᱰᱤᱡᱟᱭᱤᱱ ᱟᱨ ᱨᱤᱢᱚᱴ ᱰᱟᱴᱟ ᱴᱨᱟᱱᱥᱢᱤᱥᱚᱱ ᱴᱮᱠᱱᱚᱞᱚᱡᱤ ᱥᱟᱶ ᱢᱤᱞᱟᱹᱣ ᱠᱟᱛᱮ, ᱱᱚᱶᱟ ᱫᱚ ᱜᱟᱰᱟ, ᱫᱚᱨᱭᱟ, ᱡᱟᱜᱟ ᱟᱨ ᱮᱴᱟᱜ ᱫᱟᱜ ᱵᱚᱦᱚᱜ ᱠᱚ ᱵᱮᱵᱮᱥᱛᱟ ᱨᱮ ᱯᱟᱥᱱᱟᱣ ᱞᱮᱠᱟᱛᱮ ᱵᱮᱵᱷᱟᱨᱚᱜ ᱠᱟᱱᱟ᱾

 

ᱱᱚᱶᱟ ᱥᱤᱥᱴᱚᱢ ᱨᱮ ᱟᱥᱚᱠᱟᱭ ᱛᱮ ᱢᱤᱫᱴᱮᱱ ᱢᱚᱱᱤᱴᱚᱨᱤᱝ ᱥᱮᱱᱥᱟᱨ ᱜᱟᱫᱮᱞ, ᱢᱤᱫᱴᱮᱱ ᱰᱟᱴᱟ ᱟᱨᱡᱟᱣ ᱟᱨ ᱴᱨᱟᱱᱥᱢᱤᱥᱚᱱ ᱭᱩᱱᱤᱴ, ᱢᱤᱫᱴᱮᱱ ᱥᱚᱞᱟᱨ ᱯᱟᱣᱟᱨ ᱥᱟᱯᱞᱟᱭ ᱥᱤᱥᱴᱚᱢ, ᱟᱨ ᱢᱤᱫᱴᱮᱱ ᱯᱷᱞᱚᱴ ᱥᱴᱨᱟᱠᱪᱟᱨ ᱢᱮᱱᱟᱜ-ᱟ᱾ ᱥᱮᱱᱥᱟᱨ ᱢᱳᱰᱩᱞ ᱫᱚ ᱢᱳᱰᱩᱞᱟᱨ ᱰᱤᱡᱟᱭᱤᱱ ᱟᱯᱱᱟᱨ ᱟᱨ RS485/MODBUS-RTU ᱯᱨᱚᱴᱚᱠᱚᱞ ᱦᱚᱛᱮᱛᱮ ᱡᱚᱜᱟᱡᱩᱜᱽ ᱮᱫᱟᱭ, ᱢᱤᱫ ᱚᱠᱛᱚ ᱨᱮ ᱯᱟᱨᱟᱢᱤᱴᱟᱨ ᱟᱨᱡᱟᱣ ᱥᱟᱯᱚᱨᱴ ᱮᱫᱟᱭ ᱡᱮᱞᱠᱟ COD (UV254 ᱥᱚᱡᱷᱮ ᱯᱚᱛᱷᱤ, 0~500mg/L, ᱴᱷᱤᱠ ±5%), ᱮᱢᱚᱱᱤᱭᱟ ᱱᱟᱭᱴᱨᱚᱡᱮᱱ (0{0{0g./L}0ved), ᱮᱢᱳᱱᱤᱭᱟ ᱱᱟᱭᱴᱨᱚᱡᱮᱱ (0{0g./9}1 (ᱤᱞᱮᱠᱴᱨᱚᱠᱮᱢᱤᱠᱮᱞ ᱯᱚᱛᱷᱤ)᱾ ᱰᱟᱴᱟ ᱟᱠᱷᱲᱟ ᱭᱩᱱᱤᱴ ᱨᱮ ᱨᱤᱭᱟᱞ ᱴᱟᱭᱤᱢ ᱜᱷᱚᱴᱚᱱ ᱟᱨ ᱴᱟᱭᱤᱢ ᱥᱴᱚᱨᱮᱡᱽ ᱯᱷᱟᱱᱥᱚᱱ ᱢᱮᱱᱟᱜ-ᱟ, ᱟᱨ 2G/4G ᱱᱮᱴᱣᱟᱨᱠ ᱦᱚᱛᱮᱛᱮ ᱠᱞᱟᱣᱰ ᱯᱞᱮᱴᱯᱷᱚᱨᱢ ᱨᱮ ᱰᱟᱴᱟ ᱫᱚᱦᱚ ᱠᱟᱛᱮ ᱟᱭᱢᱟ ᱴᱟᱨᱢᱤᱱᱟᱞ ᱠᱷᱚᱱ ᱨᱤᱢᱚᱴ ᱮᱠᱥᱮᱥ ᱥᱟᱯᱚᱨᱴ ᱮᱢ ᱠᱟᱱᱟ᱾

 

ᱯᱟᱣᱟᱨ ᱥᱟᱯᱞᱟᱭ ᱥᱤᱥᱴᱚᱢ ᱫᱚ 22.1V/50W ᱥᱚᱞᱟᱨ ᱯᱮᱱᱮᱞ ᱥᱟᱶ 12VDC 20AH ᱞᱤᱛᱷᱤᱭᱚᱢ ᱵᱮᱴᱟᱨᱤ ᱢᱤᱫ ᱥᱟᱶᱛᱮ ᱢᱮᱥᱟᱞ ᱠᱟᱱᱟ, 5W ᱠᱷᱚᱱ ᱠᱚᱢ ᱥᱮ ᱵᱟᱨᱟᱵᱟᱨᱤ ᱯᱟᱣᱟᱨ ᱠᱷᱚᱨᱚᱪ ᱟᱨ ᱢᱤᱫ ᱥᱮᱱᱥᱟᱨ ᱯᱟᱣᱟᱨ ᱠᱷᱚᱨᱚᱪ 0.25W ᱠᱷᱚᱱ ᱠᱚᱢ, 5 ᱫᱤᱱ ᱠᱷᱚᱱ ᱵᱟᱹᱲᱛᱤ ᱵᱟᱹᱲᱤᱡ ᱠᱟᱹᱢᱤ ᱠᱟᱱᱟ᱾ ᱯᱷᱞᱚᱴ ᱫᱚ 414mm ᱰᱟᱭᱢᱤᱴᱟᱨ ᱤᱧᱡᱤᱱᱤᱭᱟᱨᱤᱝ ᱯᱞᱟᱥᱴᱤᱠ ᱜᱩᱞᱟᱹᱭ ᱥᱴᱨᱟᱠᱪᱚᱨ ᱠᱟᱱᱟ, ᱚᱡᱚᱱ ᱫᱚ 22kg, ᱟᱨ 304 ᱥᱴᱮᱱᱞᱮᱥ ᱥᱴᱤᱞ ᱯᱷᱤᱞᱴᱟᱨ ᱠᱟᱨᱴᱨᱤᱡᱽ ᱨᱩᱠᱷᱤᱭᱟᱹ ᱠᱚᱵᱷᱟᱨ ᱛᱮ ᱥᱟᱡᱟᱣ ᱢᱮᱱᱟᱜ-ᱟ, ᱚᱱᱟ ᱫᱚ ᱵᱷᱟᱹᱜᱤ ᱠᱚᱨᱚᱥᱚᱱ ᱨᱮᱡᱤᱥᱴᱚᱱ ᱟᱨ ᱣᱮᱵᱽ ᱨᱮᱡᱤᱥᱴᱚᱱ ᱮᱢᱚᱜ ᱠᱟᱱᱟ᱾

 

ᱛᱟᱠᱱᱤᱠᱤ ᱱᱟᱶᱟᱛᱮᱫ ᱯᱮ ᱯᱟᱦᱴᱟ ᱨᱮ ᱧᱮᱞᱚᱜ ᱠᱟᱱᱟ: ᱟᱯᱱᱟᱨ ᱫᱟᱲᱮ ᱵᱮᱵᱚᱥᱛᱟ ᱫᱚ ᱢᱟᱨᱥᱟᱞ ᱛᱮᱛᱮᱫ ᱞᱮᱠᱟᱛᱮ ᱟᱨᱡᱟᱣ ᱯᱷᱨᱤᱠᱩᱣᱮᱱᱥᱤ ᱫᱚ ᱞᱟᱲᱦᱟᱭ ᱞᱮᱠᱟᱛᱮ ᱵᱮᱵᱷᱟᱨ ᱮᱫᱟᱭ; ᱥᱮᱱᱥᱟᱨ ᱫᱚ ᱚᱠᱛᱚ ᱚᱠᱛᱚ ᱨᱮ ᱵᱟᱭᱚᱯᱷᱚᱞᱤᱝ ᱚᱪᱚᱜ ᱞᱟᱹᱜᱤᱫ ᱟᱞᱴᱨᱟᱥᱚᱱᱤᱠ ᱥᱟᱯᱷᱟ ᱥᱟᱫᱷᱚᱱ (᱐.᱗W) ᱮ ᱡᱩᱢᱤᱫ ᱮᱫᱟ; ᱟᱨ ᱢᱤᱫ ᱞᱚᱞᱚ ᱠᱷᱚᱨᱚᱪ ᱟᱞᱜᱚᱨᱤᱫᱷᱚᱢ ᱯᱮᱨᱟᱢᱤᱴᱟᱨ ᱰᱨᱤᱯᱷᱴ ᱴᱷᱤᱠ ᱮᱫᱟᱭ, ᱡᱚᱠᱷᱟ ᱦᱩᱰᱟᱹᱜ ᱞᱟᱹᱜᱤᱫ<±1% within the 0~50℃ range. The device supports plug-and-play sensor expansion, allowing for quick integration with new parameters such as chlorophyll and ORP. The cloud platform provides data curve analysis, threshold alarms, HJ-212 protocol forwarding, and other functions, supporting Excel export and map-based management to meet the needs of various environmental monitoring scenarios.

 

ᱮᱯᱞᱤᱠᱮᱥᱚᱱ ᱥᱤᱱᱟᱨᱤᱭᱚ ᱟᱨ ᱯᱨᱮᱠᱴᱤᱠᱟᱞ ᱵᱷᱮᱞᱭᱩ: ᱱᱚᱶᱟ ᱥᱤᱥᱴᱚᱢ ᱫᱚ ᱥᱟᱱᱰᱚᱝ ᱟᱨ ᱡᱤᱭᱟᱝᱥᱩ ᱯᱚᱱᱚᱛ ᱨᱮ ᱫᱟᱜ ᱯᱟᱨᱤᱵᱮᱥ ᱵᱮᱵᱚᱥᱛᱟ ᱯᱨᱚᱡᱮᱠᱴ ᱨᱮ ᱞᱟᱹᱜᱩ ᱟᱠᱟᱱᱟ᱾ ᱢᱤᱫ ᱫᱚᱨᱭᱟ ᱧᱮᱞ ᱥᱴᱮᱥᱚᱱ ᱫᱚ ᱫᱟᱹᱭᱠᱟᱹ ᱞᱮᱠᱟ ᱛᱮ ᱧᱮᱞ ᱠᱟᱛᱮ, ᱵᱩᱭ ᱥᱴᱮᱥᱚᱱ ᱫᱚ ᱟᱢᱚᱱᱤᱭᱟ ᱱᱟᱭᱴᱨᱚᱡᱮᱱ ᱟᱨ COD ᱠᱚᱱᱴᱨᱚᱡᱽ ᱨᱮᱭᱟᱜ ᱥᱟᱹᱨᱤ-ᱚᱠᱛᱚ ᱧᱮᱞ ᱛᱮ ᱫᱟᱜ ᱫᱷᱟᱯ ᱨᱮ ᱵᱷᱚᱴᱚᱱ ᱥᱚᱛᱚᱨ ᱠᱚ ᱧᱟᱢ ᱞᱟᱹᱜᱤᱫ ᱰᱟᱴᱟ ᱥᱟᱯᱚᱨᱴ ᱮᱢᱚᱜ ᱠᱟᱱᱟ; ᱜᱩᱲᱩᱵ ᱚᱠᱥᱤᱡᱮᱱ ᱟᱨ ᱯᱤ ᱮᱪ ᱜᱚᱱᱚᱝ ᱞᱤᱝᱠᱮᱡᱽ ᱵᱤᱥᱲᱤ ᱫᱚ ᱭᱩᱴᱨᱚᱯᱷᱤᱠᱮᱥᱚᱱ ᱨᱮᱭᱟᱜ ᱡᱷᱩᱠᱤ ᱧᱮᱞ ᱨᱮ ᱜᱚᱲᱚ ᱮᱢᱟᱭᱟ; ᱟᱨ ᱱᱟᱜᱟᱢᱤᱭᱟᱹ ᱰᱟᱴᱟ ᱞᱟᱣᱮᱨ ᱛᱩᱞᱟᱹ ᱡᱚᱠᱷᱟ ᱵᱷᱚᱱᱰᱚᱜ ᱠᱚᱵᱚᱡᱽ ᱯᱨᱚᱡᱮᱠᱴ ᱨᱮᱭᱟᱜ ᱯᱨᱚᱵᱷᱟᱣ ᱯᱩᱥᱴᱟᱹᱣ ᱮᱫᱟᱭ ᱾ ᱱᱚᱣᱟ ᱨᱮᱭᱟᱜ ᱜᱩᱱ ᱫᱚ ᱵᱟᱦᱨᱮ ᱵᱤᱡᱽᱞᱤ ᱵᱟᱝ ᱞᱟᱹᱠᱛᱤᱭᱟ ᱟᱨ ᱥᱟᱢᱲᱟᱣ ᱟᱞᱜᱟ ᱛᱮ ᱥᱟᱝᱜᱤᱧ ᱫᱟᱜ ᱨᱮ ᱧᱮᱞ ᱠᱷᱚᱨᱚᱪ ᱟᱹᱰᱤ ᱠᱚᱢ ᱟᱠᱟᱱᱟ, ᱡᱟᱦᱟᱸ ᱨᱮ ᱥᱮᱨᱢᱟᱠᱤᱭᱟᱹ ᱪᱟᱞᱟᱣ ᱟᱨ ᱥᱟᱢᱲᱟᱣ ᱠᱷᱚᱨᱚᱪ ᱫᱚ ᱯᱟᱨᱤᱥᱚᱱᱟᱞ ᱴᱷᱟᱶ ᱠᱷᱚᱱ ᱖᱐% ᱠᱷᱚᱱ ᱠᱚᱢ ᱜᱮᱭᱟ᱾

 

ᱥᱢᱟᱨᱴ ᱯᱟᱨᱤᱵᱷᱟᱨ ᱨᱩᱠᱷᱤᱭᱟᱹ ᱵᱮᱱᱟᱣ ᱨᱮᱭᱟᱜ ᱞᱟᱦᱟ ᱥᱟᱶᱛᱮ, ᱵᱩᱭ-ᱞᱮᱠᱟᱱ ᱫᱟᱜ ᱜᱩᱱ ᱧᱮᱞ ᱥᱴᱮᱥᱚᱱ ᱠᱚ ᱠᱟᱹᱴᱤᱡ ᱠᱟᱹᱢᱤ, ᱠᱚᱢ ᱫᱟᱲᱮ ᱠᱷᱚᱨᱚᱪ, ᱟᱨ ᱵᱟᱹᱲᱛᱤ-ᱯᱮᱨᱟᱢᱤᱴᱟᱨ ᱫᱟᱲᱮ ᱥᱮᱡ ᱩᱛᱱᱟᱹᱣ ᱠᱟᱱᱟ᱾ ᱟᱜᱟᱢ ᱨᱮ, ᱫᱟᱜ ᱜᱩᱱ ᱵᱮᱜᱟᱨ ᱨᱮᱭᱟᱜ ᱞᱟᱦᱟ ᱪᱮᱛᱟᱱ ᱦᱟᱢᱮᱴ ᱞᱟᱹᱜᱤᱫ AI ᱟᱞᱜᱚᱨᱤᱰᱚᱢ ᱡᱚᱯᱚᱲᱟᱣ ᱟᱨ ᱥᱮᱴᱮᱞᱟᱭᱤᱴ ᱨᱤᱢᱚᱴ ᱥᱮᱱᱥᱤᱝ ᱰᱟᱴᱟ ᱡᱚᱯᱚᱲᱟᱣ ᱠᱟᱛᱮ ᱢᱤᱫ ᱵᱷᱟᱹᱜᱤ ᱧᱮᱞ ᱱᱮᱴᱣᱟᱨᱠ ᱵᱮᱱᱟᱣ ᱛᱮ ᱫᱟᱜ ᱨᱮᱭᱟᱜ ᱯᱟᱨᱤᱵᱮᱥ ᱵᱮᱵᱚᱥᱛᱟ ᱨᱮ ᱟᱨᱦᱚᱸ ᱥᱩᱫᱷᱟᱹᱨ ᱟᱨ ᱫᱟᱜ ᱥᱚᱢᱯᱚᱛᱤ ᱨᱩᱠᱷᱤᱭᱟᱹ ᱟᱨ ᱴᱤᱠᱟᱹᱣ ᱩᱛᱱᱟᱹᱣ ᱞᱟᱹᱜᱤᱫ ᱛᱟᱠᱱᱤᱠᱤ ᱜᱚᱲᱚ ᱮᱢᱚᱜᱼᱟ᱾

ᱤᱱᱴᱮᱜᱽᱨᱮᱥᱚᱱ